Model: G0003-5
The Glow Wire Thermocouple allows for a test to be carried out assessing the effects of heat generated by electrical faults and overloads within electrical equipment in solid insulated materials and non-metallic enclosures containing or supporting current carrying parts with regard to ignitability and propagation of flame.
An electrically heated small loop of resistance wire Glow-wire is applied to those insulation surfaces likely to be subjected to heat generated by fault conditions or overloads. The temperature and duration of application of the glow-wire is dependant upon the operational and service conditions of the equipment under test. The glow-wire thermocouple is an integral part of this test.
The glow wire must be introduced at right angles to the test specimen with a force of 0.8 to 1.2N and the glow-wire and test specimen must be moved towards each other over a distance of up to 7mm.
Calibration of thermocouple is to be carried out at 960˚C.
Preferred test temperatures are:
650˚C
750˚C
850˚C
960˚C
Application:
Electro technical equipment
Solid combustible materials
Solid electrical insulating materials
Insulation surfaces.
Features:
Complies with very stringent requirements of the standards
Certified by FastLab. ECEFast NATA accredited laboratory No.5473
Standards:
AS/NZS 60695.2.10:2000 Glowing Hot-Wire based test method.
Options:
TS-GLOW-ASSNATA 0.5mm diameter NATA certified Glow-Wire Thermocouple.
TS-GLOW-ASSNATA1 1mm diameter NATA certified Glow-Wire Thermocouple